ProSoft MVI46-MCM SLC 500 Modbus Communication Module
  • Warehouse: Spot
  • Warranty: 365 days
  • Quality: Original module
  • Condition: New
  • Shipping method: Courier delivery

  • Contact person: LI MING
  • Contact number: +86 18059884790
  • WeChat:18059884790
  • E-mail: plc66@qq.com

Product Description
ProSoft Technology  |  Modbus Master/Slave Communication Module

ProSoft MVI46-MCM SLC 500 Modbus Communication Module

1746 Backplane In-Chassis Serial Modbus Gateway  ·  Legacy SLC500 PLC Interface

Product Overview

The MVI46-MCM is a single-slot in-chassis Modbus master/slave communication module designed for Allen‑Bradley SLC 500 (1746) PLC rack, compatible with SLC 5/02, 5/03, 5/04, 5/05 processors supporting M0/M1 file memory access. It provides two isolated serial ports, each configurable independently as Modbus RTU master or slave. It acts as a protocol gateway between SLC backplane and Modbus field devices including meters, drives, sensors, RTUs and third-party PLCs. The module has a 5000-word internal register database for asynchronous data exchange, configured via RSLogix 500 ladder logic and N-file data definitions. It is a legacy spare part widely used in retrofitting and maintenance of existing SLC automation systems.

image.png

This module is non hot-swappable, consumes 800mA @5V from the backplane, and supports baud rates up to 115.2 kbps. It is only usable in local or extended SLC racks, not remote I/O racks.

Part Number
MVI46-MCM
Platform
SLC 500 / 1746 Backplane
Serial Ports
2× Isolated RS485/RS232
Protocol
Modbus RTU Master / Slave
Data Buffer
5000 Word Register Database
Power Draw
800mA @5V Backplane

Key Features

Dual Independent Modbus Serial Ports
Each port can be set as Modbus RTU master or slave independently, supporting mixed mode. Max 100 master commands per port, baud rate up to 115.2 kbps.
M0/M1 Direct Memory Access
Uses SLC M0/M1 file mapping for fast backplane data exchange, no page switching required compared to older 3150-MCM modules.
Configuration via RSLogix 500
Port parameters and master command tables are stored in integer N-files, downloaded with ladder logic; sample ladder files are provided for integration.
Isolated Serial Interfaces
Port isolation protects the SLC backplane from ground loop and surge noise, suitable for long RS485 field wiring in process and power plants.
Status & Diagnostic LED
LED indicators for module run, backplane transfer, application status, serial activity and fault alarms for on-site troubleshooting.
Class I Div 2 Hazardous Area Rated
Certified for ISA 12.12.01 Class I Div 2, ATEX Zone 2, suitable for oil, gas and chemical process environments.
Legacy Maintenance Spare
Obsolete original production, commonly stocked as replacement for existing SLC500 systems; migration option is PLX31-EIP-MBS Modbus gateway.

Typical Applications

SLC500 PLC Modbus RTU communication for process and factory automation retrofits.
Water & Wastewater Treatment
Connect SLC500 to flow meters, level transmitters, VFDs and valve controllers via Modbus RTU.
Oil & Gas Skid Control
Legacy skid PLC communication with pressure/temperature transmitters and local SCADA.
Power Plant Auxiliary Control
SLC rack communication with energy meters, protection relays and vibration monitors.
Packaging & Material Handling
Retrofit old SLC lines to read Modbus drives, barcode readers and sensors.
Building HVAC & Chiller Systems
SLC-based BMS linking chillers and Modbus-capable HVAC controllers.
SLC500 System Maintenance
Direct replacement for failed MVI46-MCM modules in existing running SLC racks.

Frequently Asked Questions

Which SLC CPUs are compatible?
Requires SLC 5/02 (M0/M1 capable), 5/03, 5/04, 5/05; older CPUs without M0/M1 memory cannot work.
What is the difference between MVI46-MCM and 3150-MCM?
MVI46-MCM supports M0/M1 direct access, higher baud rate up to 115.2k and simpler configuration; 3150-MCM needs page memory switching and max 38.4k baud.
Is it hot-swappable?
No, power must be removed from the SLC rack before inserting or removing the module to avoid hardware damage.
Can it work in remote I/O racks?
No, it can only be installed in local SLC rack or extended local rack, remote I/O racks are not supported.
What is the migration replacement?
Modern replacement is PLX31-EIP-MBS series Modbus gateway, which uses EtherNet/IP and PCB configuration software instead of RSLogix500 N-file setup.
What should be confirmed before replacement?
Backplane power budget, CPU model, existing N-file configuration, master command table and port wiring (RS232 / RS485).


Related recommendations