Vibro-Meter RLC16 200-570-000-112 VM600 Relay Output Card
Product Brief Description
Vibro-Meter RLC16 (PN:200-570-000-112) is a 16-channel SPDT relay expansion card for Meggitt VM600 machinery protection system. It is installed on the rear side of ABE04X rack, working with MPC4 / AMC8 processing cards. It is used when the built-in relays on IOC4T/IOC8T are insufficient, outputting alarm and trip dry contacts to DCS, PLC, ESD and annunciator panels for turbine, compressor and generator protection interlock.

Features
- 16 independent Form C (SPDT) relay channels, each with NO, NC and COM screw terminal
- Hardware jumper select: Normally Energised (NE) or Normally De-Energised (NDE) for fail-safe trip logic
- Driven via VM600 backplane OC bus by MPC4 or AMC8 monitoring cards
- Hot-swappable design, can be replaced without shutting down the whole VM600 rack
- Relay contact rating: up to 10A @250VAC resistive load
- Front LED status indicator for each relay channel, easy for on-site fault checking
- 24VDC power supply from rack backplane; compatible with ABE040, ABE042, ABE056 chassis
Application Scenarios
- Gas turbine, steam turbine, generator vibration protection system
- Oil & gas compressor, pump and large fan condition monitoring & protection
- Power plant, refinery critical rotating equipment interlock and trip output
- VM600 system expansion for extra alarm / trip relay demands
- Legacy VM600 rack retrofit and spare replacement projects
FAQ
Q: What does 200-570-000-112 stand for?
A: RLC16 series base part 200-570-000; 112 represents specific hardware revision and contact configuration variant.
Q: What is the difference between RLC16 and IOC4T?
A: IOC4T is I/O measurement card with only 4 relays; RLC16 is dedicated relay expansion card with 16 relays, only for extra dry contact outputs.
Q: Is this card discontinued?
A: Original Mk1 RLC16 series is end-of-life, successor is RLC16 Mk2. Spare stock is mainly new surplus and fully tested refurbished units.
Q: Can it work alone without MPC4?
A: No, it must receive alarm/trip logic signals from VM600 processor cards such as MPC4 or AMC8 via backplane bus.
Q: What are common failure issues?
A: Relay contact burnout, channel LED no indication, backplane bus communication loss, relay stuck on or stuck off.