Vibro-Meter 200-595-081-332 VM600 MPC4 Machinery Protection Card
Product Brief Description
Vibro-Meter 200-595-081-332 is the MPC4 (Multi-Processor Card 4) for Meggitt VM600 rack-based machinery monitoring and protection system. It is the main processing CPU card of VM600, responsible for signal calculation, alarm/trip logic, data communication and driving RLC16 relay cards. It pairs with IOC4T / IOC8T input-output cards, supports vibration, position, speed and temperature monitoring for critical rotating machinery.

Features
- High-speed multi-core processor for real-time machinery protection calculations, meets API 670 standard
- Process data from IOC4T / IOC8T cards: vibration, shaft displacement, speed, acceleration signals
- Configurable alarm and trip thresholds, time delay, voting logic for protection interlock
- Backplane OC bus interface to control RLC16 relay output cards for trip & alarm dry contacts
- Dual Ethernet ports for Modbus TCP and VM600 configuration software communication
- Built-in transient data capture, waveform recording, event log and SOE fault sequence recording
- Hot-swappable, supports redundant MPC4 master/standby configuration for high-reliability turbine systems
- Front panel status LEDs for power, fault, network, run and communication diagnosis
Application Scenarios
- Gas turbine, steam turbine and generator vibration & shaft position protection
- Oil & gas centrifugal compressor, large pump and fan condition monitoring
- Power plant, refinery and chemical plant critical rotating equipment ESD interlock
- VM600 system expansion, redundant processor upgrade
- Replacement spare for existing VM600 rack maintenance
FAQ
Q: What does 200-595-081-332 mean?
A: 200-595-081 is MPC4 base part number; suffix 332 defines firmware version, communication options and conformal coating configuration.
Q: What is the difference between MPC4 and AMC8?
A: MPC4 is dedicated protection processor for safety trip logic (API670); AMC8 is mainly for condition monitoring, spectrum analysis, without safety protection function.
Q: Can MPC4 work with RLC16 200-570-000-112?
A: Yes, MPC4 sends alarm and trip commands over the OC backplane bus to drive the RLC16 relay card.
Q: What software is used for commissioning?
A;">VibroSight software, used for configuration, threshold setup, waveform download and fault diagnosis.
Q: Is this card end of life?