KIMI Phone:+86 18059884790      中文版
HONEYWEL
Honeywell CC-TAOX11 (51308353-175) Experion Series C Redundant 16-Channel Analog Output IOTA Terminal Assembly
  • Warehouse: Spot
  • Warranty: 365 days
  • Quality: Original module
  • Condition: New
  • Shipping method: Courier delivery

  • Contact person: LI MING
  • Contact number: +86 18059884790
  • WeChat:18059884790
  • E-mail: plc66@qq.com

Product Description

Honeywell CC-TAOX11 (51308353-175) Experion Series C Redundant 16-Channel Analog Output IOTA Terminal Assembly

Brief Product Description

Honeywell CC-TAOX11, part number 51308353-175, is the 12-inch redundant analog output IOTA terminal assembly for Honeywell Experion PKS Series C rack. It is designed to work with CC-PAOX01 16-channel high-density non-HART analog output IOM, providing field wiring terminals, signal path and surge protection for 4-20mA modulating output signals to control valves. Redundant IOTA hardware architecture supports dual IOM hot standby configuration for critical control loops and bumpless failover. It includes terminal blocks for field instrument wiring, built-in surge suppression, shield grounding terminals, and internal ribbon cable interface to connect to IOM module. Each channel can be configured for fail-safe mode: hold last value or preset safe output state. Fully tested surplus and refurbished Honeywell CC-TAOX11 (51308353-175) modules are available for legacy Experion PKS system maintenance, spare replacement and plant retrofit projects.


image.png

Core Product Functions

  • 12-inch redundant high-density analog output IOTA for Experion PKS Series C rack
  • Provide field wiring terminal blocks for 4-20mA modulating valve actuators
  • Matched with CC-PAOX01 16-channel non-HART analog output IOM module
  • Built-in surge suppression and shield grounding terminals to suppress field electrical interference
  • Redundant IOTA design, supports dual IOM hot standby for critical control loops
  • Transmit analog control signals from IOM to field modulating actuators
  • Supports per-channel configurable fail-safe state: hold last value or preset safe current output
  • Onboard LED indicators for channel and module fault diagnostics
  • Supports hot-swap replacement under LOTO safety procedure

Application Scenarios

  • Legacy Honeywell Experion PKS C300 DCS redundant analog output control cabinet
  • Thermal power plant boiler/turbine critical modulating control valve signal termination
  • Petrochemical, refinery plant high point count critical 4-20mA control loops requiring IOTA redundancy
  • Oil & gas, pulp & paper plant high-reliability analog output wiring and surge protection
  • Metallurgy, water treatment critical modulating valve control signal termination
  • Legacy Experion PKS redundant AO IOTA replacement, maintenance and plant retrofits

FAQ (Frequently Asked Questions)

  • Q: Analog output abnormal or control valve not responding after installing CC-TAOX11?
    A: Confirm IOTA matches CC-PAOX01 IOM, check field valve wiring and loop load resistance, inspect surge protection components, shield grounding and ribbon cable connection, verify fail-safe parameter setting.
  • Q: Does Honeywell CC-TAOX11 support hot-swap replacement?
    A: Hot swap is supported. Risk assessment and LOTO lockout-tagout must be performed before replacement to avoid unexpected valve action and process disturbance.
  • Q: What is the difference between CC-TAOX11 and CC-TAOX01?
    A: CC-TAOX11 is 12-inch redundant AO IOTA; CC-TAOX01 is 6-inch simplex AO IOTA, both compatible with CC-PAOX01 IOM.
  • Q: What IOM card matches this IOTA?
    A: Paired with CC-PAOX01 16-channel non-HART high density analog output IOM module.
  • Q: Is Honeywell CC-TAOX11 (51308353-175) available for new DCS projects?
    A: This legacy Experion Series C IOTA terminal assembly is end-of-life for new installations. Only fully tested surplus and refurbished units are supplied for existing DCS system maintenance and retrofits.


Related recommendations