GE IS230TBAIH2C Analog I/O Terminal Board (Mark VI)
High-Precision Analog Signal Acquisition & Output for GE Mark VI Speedtronic Turbine Control
1. Product Overview

The GE IS230TBAIH2C is an analog I/O terminal board designed for seamless integration with GE Mark VI Speedtronic turbine control systems, delivering reliable analog signal acquisition and output for gas/steam turbine control and critical industrial automation applications. It provides 10 configurable analog input channels (supports 2/3/4-wire transmitters, externally powered transmitters, ±5V/±10V DC voltage inputs) and 2 analog output channels (configurable as 0-20mA or 0-200mA via jumpers), enabling high-precision signal processing for turbine speed, fuel flow, pressure, and position control. The board features a 37-pin DC connector for communication with TBAI modules, two pluggable right-angle terminal blocks (36 terminals total) for field wiring, and front-panel LED indicators for power, communication, and channel faults. With 1500V AC signal isolation, it prevents cross-interference in noisy industrial environments, while a modular design with DIN-rail mounting and pluggable terminals simplifies installation and maintenance. A wide operating temperature range (-20°C to +60°C) and IP20 protection ensure reliable operation in harsh industrial settings, making it ideal for power generation, oil & gas, and petrochemical applications requiring precise analog control.


IS230TBAIH2C -3.png



Key Specifications
• Manufacturer: GE Industrial Solutions
• Model: IS230TBAIH2C (Analog I/O Terminal Board for Mark VI)
• System Compatibility: GE Mark VI Speedtronic Turbine Control System
• Input Channels: 10 Analog Inputs (2/3/4-wire, ±5V/±10V DC, 4-20mA)
• Output Channels: 2 Analog Outputs (0-20mA / 0-200mA configurable via jumpers)
• Accuracy: ±0.1% of Full Scale for Analog Inputs; ±0.2% for Analog Outputs
• Isolation: 1500V AC Signal Isolation (1 minute), 250V AC Channel-to-Channel
• Connector: 37-pin DC (for TBAI module communication), 2×18-pin pluggable terminal blocks
• LED Indicators: Power (PWR), Communication (COM), Channel Fault (CH1-CH10, OUT1-OUT2)
• Power Input: 24V DC (±10%),<15W Power Consumption
• Mounting: DIN-Rail (IP20 Protection), Dimensions: 167×145×85mm, Weight: ~0.5kg
• Operating Temperature: -20°C to +60°C, 5%–95% RH (non-condensing)

• Certifications: UL 508, IEC 61010-1, CE


IS230TBAIH2C.png


2. Core Features
• 10+2 Channel Configuration: 10 analog inputs and 2 configurable outputs for versatile signal processing.
• High Accuracy: ±0.1% FS precision ensures reliable monitoring of critical turbine parameters.
• Signal Isolation: 1500V AC isolation prevents noise interference in industrial environments.
• Jumper Configurability: Hardware jumpers for output current range (20mA/200mA) and input type selection.
• Status Monitoring: Front-panel LEDs for power, communication, and channel faults enable quick troubleshooting.
• Plug-and-Play Design: Pluggable terminal blocks and 37-pin connector simplify installation and maintenance.

• Robust Construction: DIN-rail mounting (IP20), wide temperature range, and industrial-grade components for durability.


IS230TBAIH2C -4.png



YMGK Purchase Information
This section covers key details customers care about regarding purchasing, to support your global industrial product procurement needs.
One-Stop Global Industrial Product Procurement
Sales Manager: KI MI
WeChat: 18059884790
Email: plc66@qq.com
  • Global Inventory: 121 shared inventories worldwide, enabling direct procurement

  • from overseas warehouses for faster delivery.

  • Pricing & After-Sales: Competitive prices plus reliable after-sales warranty services.
  • Customer Coverage: Serving clients across United States, Germany, Japan, South Korea,

  • United Kingdom, France, Italy, Canada, Brazil, India, Australia, Russia, Spain, Netherlands,

  • Switzerland, Sweden, Belgium, Austria, and Turkey.

  • Product Quality: All items are brand new and original. Spare parts include a 1-year warranty,

  • and all products are tested and certified.

  • Discounts: Contact us for bulk-order discounts. We also offer further price adjustments

  • if you receive lower quotes for identical products from other suppliers.

For additional inquiries, reach out to us at any time.
All product names, trademarks, brands, and logos on this site belong to their respective owners. Their use here is for identification only, and does not imply affiliation with or authorization from the rights holders.



3. Typical Applications

• Turbine Control: Speed, fuel flow, pressure, and position control in gas/steam turbines.
• Power Generation: Boiler feedwater control, generator load monitoring, and steam temperature regulation.
• Oil & Gas: Compressor pressure control, pipeline flow measurement, and separator level monitoring.
• Petrochemical: Reactor pressure control, catalyst bed temperature regulation, and flow control in chemical plants.
• Manufacturing: Process pressure/temperature control, motor speed regulation, and quality monitoring in production lines.

• System Retrofits: Replacement of aging analog I/O terminal boards in Mark VI systems to maintain control reliability.


IS230TBAIH2C -2.png


4. Installation & Maintenance
Installation: Mount on standard DIN-rail; connect 24V DC power. Wire field devices to pluggable terminals (follow input/output configuration). Connect 37-pin DC connector to TBAI module; verify LED status (steady green for normal operation).
Maintenance: Perform quarterly checks of LED status and terminal integrity. Use Mark VI diagnostic tools for channel testing. Replace pluggable terminals if damaged; clean connectors to prevent signal degradation.
Fault Diagnosis: Flashing red LED indicates channel fault or communication loss; retrieve error codes via Mark VI HMI. Check wiring (open/short circuit), terminal connections, and TBAI module communication.