KIMI Phone:+86 18059884790      中文版
PROSOFT
ProSoft MVI56E-MCMR Enhanced Modbus Master
  • Warehouse: Spot
  • Warranty: 365 days
  • Quality: Original module
  • Condition: New
  • Shipping method: Courier delivery

  • Contact person: LI MING
  • Contact number: +86 18059884790
  • WeChat:18059884790
  • E-mail: plc66@qq.com

Product Description
ProSoft Technology  ·  ControlLogix Communication Module

MVI56E-MCMR Enhanced Modbus Master/Slave Module with Reduced Data Block

SKU: MVI56E-MCMR  |  Allen‑Bradley ControlLogix Chassis  |  2 Serial Ports  |  Modbus RTU / ASCII
Ports
2 configurable serial channels
     Mode
Master or Slave per port
     Database
5000-word user register database
     Interface
RS232 / RS422 / RS485 jumper selectable

The MVI56E-MCMR is a ProSoft enhanced Modbus communication module built for Rockwell ControlLogix backplane. It features a reduced I/O data block design optimized for limited-bandwidth remote rack deployments over ControlNet. Each of the two serial ports can be independently set as Modbus Master or Slave, supporting Modbus RTU and ASCII protocols for seamless connection with legacy meters, drives, sensors, third-party PLCs and RTUs.

image.png

It operates as a native backplane I/O module, transferring Modbus data asynchronously to the ControlLogix controller. The reduced data block minimizes scheduled backplane traffic, making it the preferred choice for remote chassis applications. It is backward compatible with older MVI56-MCMR and integrates smoothly with RSLogix 5000 and ProSoft Configuration Builder.

Product Features

Reduced Data Block Architecture
Optimized small I/O transfer block to reduce backplane load, ideal for ControlNet remote racks and bandwidth-restricted networks.
Dual Independent Serial Ports
Two isolated serial ports, each configurable as Modbus Master or Slave, can run separate Modbus networks simultaneously.
Multi-Physical Layer Support
Hardware jumper selectable for RS232, RS422 or RS485, supporting 2-wire and 4-wire wiring topologies.
5000-Word Shared Register Database
User-configurable register space for holding coils, discrete inputs, input registers and holding registers across both ports.
Backplane Asynchronous Data Transfer
Modbus field communication and backplane tag exchange run independently, avoiding scan delays for the ControlLogix processor.
RSLogix 5000 Native Integration
Works with RSLogix 5000 V16+, supports custom Add-On Instructions and tag-based data mapping without complex ladder logic.
CIPconnect Remote Diagnostics
Supports remote configuration and diagnostics through ControlLogix Ethernet modules via CIPconnect in ProSoft Configuration Builder.
LED Diagnostic Status Display
On-board status LEDs and diagnostic indicators for power, backplane, port activity and communication faults for quick troubleshooting.
Backward Compatibility
Drop-in replacement for legacy MVI56-MCMR, minimal program changes required during upgrade or spare replacement.
Industrial Certification
UL, cUL and CE certified for industrial control cabinets, suitable for standard factory and process automation environments.

Application Scenarios

ControlNet Remote Rack Systems
Primary use case for remote ControlLogix chassis where limited ControlNet bandwidth requires reduced scheduled data size.
Water & Wastewater Automation
Connect Modbus flow meters, level transmitters, analyzers and pump VFDs to ControlLogix SCADA and control systems.
Power & Utility Control
Interface energy meters, protection relays and power quality instruments to DCS and generator control systems.
Process Manufacturing
Integrate temperature controllers, weighing systems, barcode readers and legacy Modbus devices into Rockwell automation platforms.
Retrofit & Spare Replacement
Upgrade or replace old MVI56-MCMR modules in running plants without major system rework.
Oil & Gas Auxiliary Control
Link remote Modbus RTUs, pressure sensors and valve controllers to central ControlLogix racks.

Frequently Asked Questions

Q: What is the difference between MVI56E-MCMR and MVI56E-MCM?
A: MVI56E-MCMR uses a reduced I/O data block optimized for ControlNet remote racks with limited bandwidth. MVI56E-MCM uses a larger standard data block and is recommended for normal EtherNet/IP racks without bandwidth constraints.
Q: Can each serial port run as Master or Slave independently?
A: Yes. Port 1 and Port 2 can be individually configured as Modbus Master or Slave, supporting mixed-mode operation on the same module.
Q: Which Modbus protocols are supported?
A: Modbus RTU and Modbus ASCII. It supports standard Modbus function codes for coils, discrete inputs, input registers and holding registers.
Q: Is this module compatible with all ControlLogix racks?
A: It fits standard 1756 ControlLogix chassis and communicates over the ControlLogix backplane. It is compatible with RSLogix 5000 version 16 and above.
Q: How do I select RS232 / RS422 / RS485?
A: Physical layer selection is set via hardware jumpers on the module for each port before power-up.
Q: Can I use it to replace an older MVI56-MCMR?
A: Yes, it is designed as a drop-in upgrade replacement. Minor configuration validation is recommended before commissioning.
Q: What software is used for configuration?
A: ProSoft Configuration Builder (PCB) is used for module setup, mapping and diagnostics. It also supports CIPconnect remote access over the Rockwell network.
Q: How to confirm compatibility before ordering?
A: Please provide your chassis type, controller firmware version, network type (ControlNet or EtherNet/IP) and existing module part number. We will verify revision and suitability before shipment.


Related recommendations