DEIF | Delomatic-4 Power Control Module
DEIF PCM 4.1 Delomatic-4 Power Control Module
DM-4 PMS Core CPU & Power Supply Unit · Marine Generator Management Controller
Product Overview
The DEIF PCM 4.1 is the integrated power and control core module for the Delomatic-4 (DM-4) marine and offshore power management system. It combines rack power supply, main CPU, I/O router and multi-communication interfaces in one 8TE slot card. It handles generator synchronization, load sharing, breaker control, protection logic and ARC-net inter-DGU communication. This variant is mainly supplied as a spare replacement part, equipped with 3 CAN bus channels, 1 RS485, DM-4 LAN and USB service port. It works with IOM4.1 I/O modules to build distributed generator control units for ship power plants and offshore platforms.

It runs the full PMS application logic, collects measurements from IOM modules, executes auto-start/stop, synchronisation and load distribution, and communicates with ship SCADA, alarm systems and local HMI. It supports battery voltage monitoring and is powered by 24V DC auxiliary supply.
System Platform
Delomatic-4 DM-4 PMS
Communication Ports
3×CAN, 1×RS485, DM-4 LAN, USB
Core Function
Generator PMS Control & ARC-net Master
Key Features
All-in-one CPU + Power Supply + I/O Router
Integrated rack power supply, main processor and I/O bus router, directly paired with IOM4.1 modules for analogue/digital signal acquisition and relay output control.
Full PMS Generator Control Logic
Supports automatic start/stop, synchronisation, active/reactive load sharing, breaker interlock, generator protection and priority management for multi-generator bus systems.
ARC-net Inter-DGU Communication
Built-in ARC-net interface for high-speed data exchange between multiple DGU units, coordinating parallel operation and bus transfer across the whole power plant.
Multi-Bus Communication Interface
3 CAN bus channels, 1 configurable RS485 (Modbus RTU), dedicated DM-4 LAN and USB service port for local commissioning, parameter upload and firmware upgrade.
Battery Voltage Monitoring
Onboard measurement of DC battery bank voltage, providing supervision for emergency backup power on vessels and offshore installations.
Marine-Grade Industrial Design
Compliant with marine environmental standards, stable under vibration, humidity and wide temperature variation, designed for continuous 24/7 operation on board.
Spare Replacement Version
PCM 4.1 is mainly for maintenance spare parts, while PCM 4.5 is the newer standard version with extra Ethernet and RS485 ports for TCP/IP communication.
Typical Applications
Delomatic-4 DM-4 power management for marine and offshore generator sets.
Commercial Cargo & Container Vessels
Main and auxiliary generator parallel control and power management for cargo ships.
Offshore Oil & Gas Platforms
Island-mode and grid-parallel PMS for offshore generator power plants.
Fishing Vessels & Workboats
Compact multi-generator control for fishing boats, tugboats and support vessels.
Ship SCADA & Alarm Integration
Data exchange between PMS and ship alarm monitoring system, bridge control and HMI.
DM-4 DGU Rack Maintenance
Fault replacement of the core PCM controller in existing Delomatic-4 generator racks.
Shore Power & Bus Transfer Control
Automatic transfer between generator power and shore supply for vessels in port.
Frequently Asked Questions
What system is DEIF PCM 4.1 used for?
It is the core power control module for DEIF Delomatic-4 DM-4 marine power management system, used as the main CPU of each DGU generator control unit.
What is the difference between PCM 4.1 and PCM 4.5?
PCM4.1: 3×CAN, 1×RS485, no Ethernet, mainly spare replacement. PCM4.5: 2×CAN, 2×RS485, 1×Ethernet, supports Modbus TCP, is the current standard version.
Which I/O module works with PCM 4.1?
It matches the IOM4.1 I/O module, which provides analogue input, binary input and relay output channels for generator measurement and control.
How to commission PCM 4.1 after replacement?
Set the DGU ID rotary switch and jumpers, upload the original application parameter file, verify communication and test generator synchronisation and load sharing.
Does PCM 4.1 support redundant ARC-net?
PCM4.1 does not support redundant ARC-net; redundant ARC communication is available on PCM4.5 variant.
What needs to be confirmed before ordering replacement?
Confirm the original part number, firmware version, DGU ID setting, ARC-net topology and whether the project requires redundant communication.