Agilent E1406A | VXI GPIB Command Module (1-Slot C-Size Message-Based Commander)
Slot 0 controller, GPIB-to-VXI interface, and SCPI command translation for seamless integration of VXI test systems in aerospace, automotive, and electronics manufacturing
1. Product Overview

The Agilent E1406A is a C-size, 1-slot VXI message-based commander that serves as the Slot 0 controller and Resource Manager for VXI mainframes, acting as a VMEbus system controller and GPIB (IEEE-488)-to-VXIbus interface to enable transparent communication with any manufacturer’s message-based VXI modules. It features 2 MB RAM, 1.75 MB Flash memory, and 512 KB shared memory, with downloadable drivers for programming Agilent register-based devices via SCPI (Standard Commands for Programmable Instruments), translating SCPI commands for register-based instruments to simplify programming. Equipped with MXIbus Resource Manager for VXIbus extensions, it supports high-throughput multi-mainframe systems, flexible triggering/clock interfacing (synchronizing VXI backplane 10 MHz clock to external TTL signals), and Agilent IBASIC for test automation. With GPIB (IEEE-488), RS-232, and VMEbus interfaces, it complies with VXIbus standards, IEC 61010-1 safety, and EMC certifications, operating from 0°C to +55°C for reliable deployment in aerospace, automotive, electronics manufacturing, and semiconductor test environments, ensuring seamless VXI system integration and efficient test automation.

E1406A(1).png


Key Specifications
• Model: E1406A | Agilent VXI GPIB Command Module (1-Slot C-Size)
• Form Factor: 1-Slot C-size VXI message-based commander (Slot 0 & Resource Manager)
• Memory: 2 MB RAM max, 1.75 MB Flash max, 512 KB shared memory max
• Interfaces: GPIB (IEEE-488), RS-232, VMEbus, MXIbus (for VXIbus extensions)
• Clock & Timing: 10 MHz VXI backplane clock (CLK10), external TTL synchronization; 0.005% clock accuracy
• Programming: SCPI command translation, Agilent IBASIC support, downloadable driver compatibility
• Power Supply: +5 V DC (4 A), ±12 V DC (0.5 A each); Power Consumption: 25 W typical
• Environmental: Operating: 0°C to +55°C; Storage: -40°C to +70°C; Humidity: 5–95% (non-condensing)

• Certifications: VXIbus compliance, IEC 61010-1, EMC (EN 55022, EN 55024)


E1406A(3).png


2. Core Features
• Slot 0 & Resource Manager: Centralized control and resource allocation for VXI mainframes
• GPIB-to-VXI Interface: Transparent communication between GPIB controllers and VXI modules
• SCPI Command Translation: Simplifies programming of register-based VXI instruments
• MXIbus Resource Manager: High-throughput multi-mainframe VXI system expansion
• Flexible Clock Synchronization: Synchronizes 10 MHz backplane clock to external TTL signals
• Agilent IBASIC: Test automation scripting for repeatable measurements
• Downloadable Drivers: Supports custom driver integration for register-based devices

• Compact 1-Slot C-Size: Space-efficient design for VXI mainframe deployment


E1406A(6).png


3. Typical Applications
• Aerospace: Avionics test systems; satellite payload testing; flight control module validation
• Automotive: ECU (Engine Control Unit) testing; powertrain component validation; ADAS sensor calibration
• Electronics Manufacturing: Semiconductor ATE (Automatic Test Equipment); PCB functional testing; communication module verification
• Industrial Automation: Test & measurement for process control instruments; factory automation system validation
• R&D Labs: Multi-instrument test setups; high-speed data acquisition; custom test system development
4. Installation & Maintenance
Installation: Insert into VXI mainframe Slot 0; connect GPIB (IEEE-488) to controller; wire RS-232 for remote control; link MXIbus for multi-mainframe expansion; load drivers to Flash memory; configure via Agilent VIC (VXI Installation Consultant); power on and verify Resource Manager initialization.
Maintenance: Weekly: Check status LEDs (Power, GPIB, VME, MXI, Fault); Monthly: Verify GPIB/VME communication and memory integrity; Annual: Test clock synchronization and SCPI command translation; update firmware and clean module contacts.
Safety Notes: Power off mainframe before insertion/removal; use shielded cables for GPIB/RS-232; ensure proper grounding for EMC compliance; use Agilent-certified drivers to maintain SCPI compatibility.
Technical Document | Agilent E1406A | VXI GPIB Command Module for Test & Measurement Automation
YMGK Purchase Information
This section covers key details customers care about regarding purchasing, to support your global industrial product procurement needs.
One-Stop Global Industrial Product Procurement
Sales Manager: KI MI
WeChat: 18059884790
  • Global Inventory: 121 shared inventories worldwide, enabling direct procurement from overseas warehouses for faster delivery.
  • Pricing & After-Sales: Competitive prices plus reliable after-sales warranty services.
  • Customer Coverage: Serving clients across United States, Germany, Japan, South Korea, United Kingdom, France, Italy, Canada, Brazil, India, Australia, Russia, Spain, Netherlands, Switzerland, Sweden, Belgium, Austria, and Turkey.
  • Product Quality: All items are brand new and original. Spare parts include a 1-year warranty, and all products are tested and certified.
  • Discounts: Contact us for bulk-order discounts. We also offer further price adjustments if you receive lower quotes for identical products from other suppliers.
For additional inquiries, reach out to us at any time.
All product names, trademarks, brands, and logos on this site belong to their respective owners. Their use here is for identification only, and does not imply affiliation with or authorization from the rights holders.
Related recommendations