HIMA X-BLK01 | HIMax I/O Slot Blank Module
Protective blank module for unused I/O slots in HIMax safety controllers - maintains system integrity, prevents dust ingress, and ensures safe operation in industrial environments
1. Product Overview
The HIMA X-BLK01 is a blank module designed specifically for unused I/O slots in HIMax safety controller systems, serving as a protective cover to maintain system integrity, prevent dust and debris ingress, and ensure safe operation in industrial environments. It occupies empty slots to preserve proper airflow balance within the HIMax chassis, prevents accidental contact with live components, and supports flexible system configuration and expansion. Constructed from industrial-grade materials, it offers durable protection against harsh conditions, with a modular design for tool-free installation in HIMax racks. The module is certified for use in safety systems up to IEC 61508 SIL 3, TÜV approved, operating temperature range of 0°C to +60°C, making it ideal for process industries, oil & gas, and manufacturing requiring SIL 3 safety compliance.

Key Specifications
• Model: X-BLK01 (X-BLK 01) | HIMax I/O Slot Blank Module
• Compatibility: HIMA HIMax safety controller systems
• Type: Protective blank module for unused I/O slots
• Function: Dust protection, airflow maintenance, electrical safety isolation
• Material: Industrial-grade durable construction
• Mounting: Tool-free installation in HIMax chassis slots
• Certification: IEC 61508 SIL 3, TÜV approved
• Environmental: Operating Temperature: 0°C to +60°C (+32°F to +140°F); Storage: -40°C to +85°C (-40°F to +185°F); Humidity: 5% to 95% (Non-condensing)
• Dimensions: Matches HIMax I/O module form factor (120mm × 30mm × 160mm typical); Net Weight: 0.2 kg
• Origin: Manufactured in Germany

2. Core Features
• Slot Protection: Shields unused I/O slots from dust, moisture, and debris in industrial environments
• Airflow Maintenance: Occupies empty slots to preserve proper chassis airflow for system cooling efficiency
• Safety Isolation: Prevents accidental contact with live backplane components, enhancing operational safety
• Tool-Free Installation: Modular design for quick, seamless fitting into HIMax chassis without additional tools
• SIL 3 Compliance: Meets IEC 61508 SIL 3 safety standards for critical applications
• Durable Construction: Industrial-grade material for long-term use in harsh industrial settings
• System Flexibility: Supports future I/O expansion by reserving empty slots in HIMax racks

YMGK Purchase Information
This section covers key details customers care about regarding purchasing, to support your global industrial product procurement needs.
One-Stop Global Industrial Product Procurement
Sales Manager: KI MI
WeChat: 18059884790
Global Inventory: 121 shared inventories worldwide, enabling direct procurement
from overseas warehouses for faster delivery.
- Pricing & After-Sales: Competitive prices plus reliable after-sales warranty services.
Customer Coverage: Serving clients across United States, Germany, Japan, South Korea,
United Kingdom, France, Italy, Canada, Brazil, India, Australia, Russia, Spain, Netherlands,
Switzerland, Sweden, Belgium, Austria, and Turkey.
Product Quality: All items are brand new and original. Spare parts include a 1-year warranty,
and all products are tested and certified.
Discounts: Contact us for bulk-order discounts. We also offer further price adjustments
if you receive lower quotes for identical products from other suppliers.
For additional inquiries, reach out to us at any time.
All product names, trademarks, brands, and logos on this site belong to their respective owners. Their use here is for identification only, and does not imply affiliation with or authorization from the rights holders.
3. Typical Applications
• Process Control: Petrochemical refineries, chemical plants, and pharmaceutical facilities using HIMax SIL 3 safety systems
• Manufacturing: Automotive assembly lines, packaging machinery, and food/beverage processing with HIMax safety controllers
• Oil & Gas: Offshore platforms, pipeline control, and wellhead monitoring systems requiring SIL 3 compliance
• Power Generation: Turbine control, auxiliary systems, and grid management with HIMax safety infrastructure
• Commissioning & Maintenance: Temporary slot protection during system setup, upgrades, or downtime

4. Installation & Maintenance
Installation: Align with unused HIMax I/O slot; push firmly until latched (no tools needed); ensure secure fit to maintain chassis sealing.
Maintenance: Weekly: Inspect module fit and chassis sealing; check for dust accumulation. Monthly: Remove and clean module surface; verify slot protection integrity. Annual: Replace if damaged; confirm compatibility with HIMax firmware updates.
Safety Notes: Always install in unused slots before system power-up; do not remove during operation; replace damaged modules immediately to maintain SIL 3 compliance.
Technical Document | HIMA X-BLK01 | HIMax I/O Slot Blank Module for Industrial Safety Systems