KIMI Phone:+86 18059884790      中文版
GE
Home > GE
GE 869-E-P5-P5-B5-H-S-S-A-L-A-M-M-P-F-B-SE-N-N-B-N Multilin 869 Motor Protection Relay
  • Warehouse: Spot
  • Warranty: 365 days
  • Quality: Original module
  • Condition: New
  • Shipping method: Courier delivery

  • Contact person: LI MING
  • Contact number: +86 18059884790
  • WeChat:18059884790
  • E-mail: plc66@qq.com

Product Description
GE MULTILIN  ·  869-E-P5-P5-B5-H-S-S-A-L-A-M-M-P-F-B-SE-N-N-B-N

869-E-P5-P5-B5-H-S-S-A-L-A-M-M-P-F-B-SE-N-N-B-N Multilin 869 Motor Protection Relay

SKU: 869-E-P5-P5-B5-H-S-S-A-L-A-M-M-P-F-B-SE-N-N-B-N  |  Multilin 869 Motor Protection Relay  |  USA origin  |  Active / legacy MRO spare
Core Application
Medium & large motor protection & control
     Type
Motor protection relay
     CT Rating
5A secondary
     Status
Legacy MRO spare

The GE Multilin 869-E-P5-P5-B5-H-S-S-A-L-A-M-M-P-F-B-SE-N-N-B-N is a fully featured motor protection relay from GE’s 8 Series platform. It provides comprehensive protection, metering, control and fault diagnostics for induction and synchronous motors. This P5 configuration uses 5A CT inputs, includes rich I/O, sequence-of-events recording, motor thermal modeling, and Ethernet/serial communication for DCS/SCADA integration. Widely deployed in power plants, oil & gas, water treatment, mining and industrial process facilities.

Typical deployment;">Medium voltage motor control center, large pump / fan / compressor motor, industrial MCC cabinet, plant DCS network, motor condition monitoring, overload, short circuit, earth fault and stall protection.

image.png

Product Features

Full Motor Protection Suite
Thermal overload, locked rotor, stall, short circuit, earth fault, phase unbalance, loss of phase, reverse power protection.
5A CT Secondary Input
P5 suffix = 5A current transformer input, standard for medium voltage motor installations.
Built-in Thermal Model
Adaptive thermal capacity tracking, start inhibit, safe restart lockout for motor winding protection.
Sequence of Events & Fault Recording
High-resolution SOE, oscillography / fault event capture for post-fault analysis.
Multi-Protocol Communication
Ethernet, Modbus, DNP3, IEC 61850 optional, for SCADA and DCS connectivity.
Local HMI & Metering
Front panel display, real-time voltage / current / power / energy metering, alarm indication.
Rich Configurable I/O
Digital inputs, trip outputs, auxiliary alarm contacts, breaker control logic.
Rack Mount MCC Form Factor
Standard panel cutout, designed for MCC compartment installation, widely stocked MRO spare.

Application Scenarios

MV Induction Motor Protection
Primary protection for medium voltage pumps, fans and conveyors.
Oil & Gas Compressor Motors
Critical motor protection for upstream and refining process units.
Water & Wastewater Treatment Plant
Large intake pump, blower motor control and protection.
Mining & Heavy Industry Drives
Conveyor, crusher, hoist motor with locked rotor and stall protection.
Power Plant Auxiliary Motors
FD fan, ID fan, BFP motor protection and condition monitoring.
MCC MRO Replacement Spare
Direct drop-in replacement for existing 869 series relays in service MCCs.

Frequently Asked Questions

Q: What is 869-E-P5-P5-B5-H-S-S-A-L-A-M-M-P-F-B-SE-N-N-B-N?
A: GE Multilin 869 motor protection relay, 5A CT version, for medium and large AC motor protection, control and metering.
Q: What is the difference between P1 and P5 suffix?
A: P1 = 1A CT secondary input; P5 = 5A CT secondary input, this model is P5 (5A).
Q: What happens if this relay fails?
A: Motor protection and breaker control are lost; motor will run without protection, risk of winding burnout, short circuit and fire hazard.
Q: HS code for this item?
A: HS 853649, motor protective relay / electrical protective device.
Q: How to confirm compatibility before ordering?
A: Confirm CT ratio (1A /5A), power supply, I/O requirement, firmware version, communication protocol and wiring scheme.


Related recommendations