Metrix 5485C-007-040 High Temperature Sensor
Brief Description
5485C-007-040 is a Metrix moving-coil seismic velocity transducer with integral armored cable. It is self-generating and designed for high-temperature vibration monitoring of turbines, compressors and other rotating machinery, outputting AC velocity signal to vibration monitors and PLC systems.

Product Features & Functions
- Moving-coil design, self-generating, no external power supply required
- Sensitivity: ±28.3 mV/in/sec, frequency response 10 Hz ~ 1000 Hz
- Integral fixed armored cable, cable length 40 feet (12 meters)
- Stainless steel hermetically sealed housing, zero-friction coil suspension
- 1/4-28 UNF mounting thread for easy installation on equipment casing
- Available with ATEX/CSA approvals for hazardous area applications
- Excellent low-frequency performance, good resistance to cross-axis vibration and high-g shock
Application Scenarios
- Gas turbine, steam turbine and centrifugal compressor vibration monitoring
- Power plant, oil & gas and refinery rotating machinery protection systems
- Fan, pump and gearbox condition monitoring and predictive maintenance
- Bently Nevada, Metrix or third-party vibration monitoring racks
- Rotating equipment overhaul and spare sensor replacement
FAQ
Q: What does 007-040 stand for?
A: 007 indicates sensitivity code; 040 means 40ft integral armored cable version.
Q: Does this sensor need external power?
A: No, it is self-generating, relying on coil movement to produce velocity signal.
Q: Can it be used in explosive zones?
A: Yes, hazardous area certification options are available; confirm full model code before ordering.
Q: Will you test the sensor before shipment?
A: Each unit is sensitivity and continuity tested. Test report can be provided upon request.