Allen‑Bradley 1797-PS1E FLEX Ex Intrinsically Safe Power Supply

Product Brief Description

Allen‑Bradley 1797-PS1E is a certified intrinsically safe power supply for the Rockwell 1797 FLEX Ex I/O system. It accepts wide-range 85–253 VAC input and delivers four independent, galvanically isolated intrinsically safe DC output channels. Each channel is energy-limited to meet ATEX and IECEx requirements for Zone 1 and Zone 22 hazardous locations, supplying power to FLEX Ex I/O modules and field instruments in explosive gas and dust environments. It features flameproof enclosure design and is widely used for hazardous area distributed I/O power feeding.

image.png

Product Functions

  • Convert 85–253 VAC mains power into four isolated intrinsically safe DC outputs
  • Each channel limited to 8.5 W maximum power, 9.5 V max open voltage and 1 A short-circuit current
  • Galvanic isolation between input and outputs, and channel-to-channel isolation to prevent fault propagation
  • Energy-limiting protection to ensure intrinsic safety for classified hazardous zones
  • Flameproof Ex d housing with increased safety terminals for reliable field installation
  • Provide stable power supply for FLEX Ex analog, digital and HART I/O modules
  • Built-in circuit protection against overcurrent, short-circuit and over-temperature conditions
  • Support ControlNet Ex distributed I/O architecture for process automation systems

Application Scenarios

  • Oil & gas offshore platforms, refineries and pipeline compressor stations
  • Chemical and petrochemical plants with explosive gas and dust hazardous areas
  • Process industry distributed FLEX Ex I/O stations connected to ControlLogix PLC
  • Hazardous area temperature, pressure, flow and level transmitter monitoring loops
  • ATEX / IECEx Zone 1 and Zone 22 certified field control cabinet power supply
  • System upgrade, spare replacement and maintenance of existing FLEX Ex installations

FAQ

Q1: What is the input voltage of 1797-PS1E?

A1: 85–253 VAC, 47–63 Hz wide AC input range.

Q2: How many intrinsically safe output channels does it have?

A2: It has four independent galvanically isolated IS output channels, 8.5W per channel.

Q3: What hazardous zones can this power supply be used in?

A3: It is certified for ATEX/IECEx Zone 1 (gas) and Zone 22 (dust) hazardous locations.

Q4: Which I/O system does it match?

A4: It is designed exclusively for the 1797 FLEX Ex intrinsically safe I/O system, paired with ControlNet Ex adapters.

Q5: Will a short circuit on one channel affect the other channels?

A5: No, each channel is independently limited and isolated; faults on one channel will not spread to other channels.