Relcom F802 (MTL / Eaton Relcom F802) FOUNDATION Fieldbus H1 Power Module

Product Description

The Relcom F802 is an 8-channel isolated FOUNDATION Fieldbus H1 power supply module, used with F890 backplane system. It provides conditioned, galvanically isolated power for 8 FF H1 segments, with built-in short-circuit protection, bus termination and fault alarm function. It supports simplex or redundant load-sharing operation, widely deployed in DeltaV and other DCS fieldbus networks for oil & gas, chemical process plants.

image.png

Features

  • Part Number: F802, Brand: Relcom (MTL / Eaton)
  • Bus type: FOUNDATION Fieldbus H1 (31.25 kbps)
  • Output: 28–30 VDC, max 500 mA per segment, current limit >520 mA
  • Channel quantity: 8 independent fieldbus segments
  • Redundancy: Two F802 modules for redundant load sharing; simplex single module also supported
  • Isolation: Galvanic isolation between input side and each fieldbus segment
  • Built-in: Automatic bus termination, segment short-circuit protection, fault alarm relay, LED status indicator
  • Mounting: Used on F890 carrier backplane, DIN rail frame installation
  • Certification: ATEX / IECEx intrinsically safe certified for hazardous area
  • Operating temperature: -25 ℃ ~ +60 ℃, passive cooling
  • Manufacturer Status: Mature fieldbus power module, available original new, surplus and fully tested refurbished units
  • Typical gross weight: approx 1.6 kg, origin: United Kingdom
  • Matching system: F890 rack, Emerson DeltaV, Foxboro DCS FF H1 fieldbus network

Applications

  • Chemical, refinery, oil & gas FOUNDATION Fieldbus H1 fieldbus power supply
  • Emerson DeltaV DCS fieldbus segment power and isolation
  • Hazardous area instrument network for LNG terminal, pipeline, offshore platform
  • Process plant fieldbus network upgrade, spare replacement and maintenance

FAQ

Q: What is the difference between F801 and F802?
A: F801 is 24V / 350mA per segment; F802 is higher power 30V / 500mA version for segments with more field instruments.

Q: Can F802 work alone without F890 backplane?
A: No, F802 is the power module, it must be installed on F890 carrier baseplate to complete 8-segment fieldbus power system.

Q: Does it support Profibus PA?
A: It is mainly designed for FOUNDATION Fieldbus H1; Profibus PA uses similar physical layer but normally matched with dedicated PA power modules.