News
Featured
Contact Us
Contact: POWER DUKE
Phone: +86 18059884790
E-mail: plc66@qq.com
Add: fujian xiamen
- Warehouse: Spot
- Warranty: 365 days
- Quality: Original module
- Condition: New
- Shipping method: Courier delivery
- Contact person: LI MING
- Contact number: +86 18059884790
- WeChat:18059884790
- E-mail: plc66@qq.com
FOXBORO 873RS‑BIPFGZ‑T Resistivity Analyzer Transmitter
Product Description
The 873RS‑BIPFGZ‑T is a Foxboro 873 series industrial resistivity analyzer transmitter, designed for online water quality monitoring. It accepts signals from resistivity sensors and calculates water resistivity or conductivity values. Equipped with a metal field‑mount enclosure, local LED display and membrane keypad, it provides isolated analog output and relay alarm contacts. This transmitter can work independently or connect to Foxboro I/A Series DCS systems, widely used for high‑purity water and deionized water measurement under continuous industrial operating conditions.

Product Functions
- Collect and process signals from one or two resistivity sensors
- Real‑time calculation and display of liquid resistivity (MΩ·cm) and conductivity
- Temperature compensation to eliminate measurement deviation caused by water temperature changes
- Isolated 4‑20mA analog output for DCS or PLC system transmission
- Programmable high/low limit relay alarm outputs for abnormal water quality
- Local keypad calibration, parameter setting and measurement mode configuration
- Built‑in self‑diagnosis for sensor break, short‑circuit and circuit faults
- Field metal enclosure, suitable for on‑site pipe or panel installation
Application Scenarios
- Power plant boiler feedwater and condensed water purity monitoring
- Electronics factory ultra‑pure water (UPW) production and treatment systems
- Pharmaceutical and food industry deionized water process monitoring
- Reverse osmosis RO, ion exchange and water purification equipment
- Chemical plant cooling water and steam condensate quality analysis
- Water treatment DCS online water‑quality continuous monitoring cabinets
Common Problems
- No reading or blank display:power supply failure, loose power terminal connection
- Unstable and jumping resistivity values:sensor fouling, cable interference or poor grounding
- Measurement drift and large error:calibration expiration, sensor aging or temperature compensation failure
- 4‑20mA output deviation:output circuit damage, incorrect range configuration
- Continuous false alarm:wrong alarm threshold setting or sensor surface contamination
- Sensor fault diagnostic alert:cable open/short circuit, electrode damage
- Intermittent signal loss:moisture in terminal compartment or vibration‑induced poor contact



