Honeywell CC-IP0101 51410056-175 PROFIBUS DP Gateway Module
PROFIBUS DP to Ethernet Gateway for Experion PKS C300 Control System
1. Product Overview

The Honeywell CC-IP0101 (51410056-175) is a high-performance PROFIBUS DP gateway module designed for seamless integration between PROFIBUS DP field devices and Honeywell Experion PKS C300 control systems. As a critical communication bridge, it supports dual DP networks, master/slave operation modes, and data rates from 9.6 kbps to 12 Mbps, enabling reliable data exchange with up to 127 field devices per DP port. With dual Ethernet ports for network redundancy, industrial-grade design, and compatibility with Experion PKS engineering tools, it ensures stable operation in harsh industrial environments, making it ideal for process automation, oil & gas, power generation, and manufacturing applications.


CC-IP0101 51410056-175.png


Key Specifications
• Model: CC-IP0101 | Part Number: 51410056-175 | Brand: Honeywell | Series: Experion PKS C300
• Type: PROFIBUS DP Gateway Module (Dual DP Port)
• Protocol: PROFIBUS DP V0/V1, Modbus TCP, OPC UA (for Ethernet integration)
• Data Rate: 9.6 kbps to 12 Mbps (auto-negotiation for DP)
• Device Capacity: Up to 127 field devices per DP port (max 254 total for dual ports)
• Power Supply: 24 VDC (18–32 V range), Power Consumption: ~6 W
• Connectors: 2 x PROFIBUS DP (9-pin D-Sub), 2 x RJ45 Ethernet (10/100 Mbps), IOTA Termination
• Indicators: Power (Green), DP1 Status (Amber), DP2 Status (Amber), Ethernet Link (Green), Fault (Red)
• Operating Temperature: -20°C to +60°C; Storage Temperature: -40°C to +85°C
• Humidity: 5-95% (non-condensing); Protection Class: IP20 (module)
• Certifications: CE, UL, RoHS Compliant
• Dimensions: 190 mm (W) × 69 mm (H) × 23 mm (D); Weight: 0.3 kg
• Compatibility: Honeywell C300 Controller, Experion PKS Engineering Environment
2. Core Features
• Dual PROFIBUS DP Ports: Supports two independent DP networks for redundancy or expanded device capacity
• Master/Slave Flexibility: Operates as PROFIBUS DP master or slave to adapt to diverse network topologies
• High-Speed Data Transfer: 12 Mbps max DP rate ensures real-time control and monitoring
• Network Redundancy: Dual Ethernet ports enable redundant topologies for continuous communication
• Advanced Diagnostics: LED indicators and event logging for fast fault detection and troubleshooting
• Easy Configuration: Integrated with Experion PKS tools for intuitive gateway setup and device management

• Industrial-Grade Reliability: Wide temperature range and robust design for harsh process environments


CC-IP0101 51410056-175 (3).png



YMGK Purchase Information
This section covers key details customers care about regarding purchasing, to support your global industrial product procurement needs.
One-Stop Global Industrial Product Procurement
Sales Manager: KI MI
WeChat: 18059884790
Email: plc66@qq.com
  • Global Inventory: 121 shared inventories worldwide, enabling direct procurement from overseas warehouses for faster delivery.
  • Pricing & After-Sales: Competitive prices plus reliable after-sales warranty services.
  • Customer Coverage: Serving clients across United States, Germany, Japan, South Korea, United Kingdom, France, Italy, Canada, Brazil, India, Australia, Russia, Spain, Netherlands, Switzerland, Sweden, Belgium, Austria, and Turkey.
  • Product Quality: All items are brand new and original. Spare parts include a 1-year warranty, and all products are tested and certified.
  • Discounts: Contact us for bulk-order discounts. We also offer further price adjustments if you receive lower quotes for identical products from other suppliers.
For additional inquiries, reach out to us at any time.
All product names, trademarks, brands, and logos on this site belong to their respective owners. Their use here is for identification only, and does not imply affiliation with or authorization from the rights holders



3. Typical Applications

• Oil & Gas: Refinery process control, pipeline monitoring, offshore platform automation
• Power Generation: Turbine control, generator monitoring, substation automation
• Petrochemical: Reactor temperature/pressure control, batch process automation
• Manufacturing: Production line automation, robot coordination, machine tool control

• Water Treatment: Pump/valve control, flow monitoring, chemical dosing system integration


CC-IP0101 51410056-175 (2).png


4. Installation & Maintenance
Installation: Mount on IOTA termination assembly; Connect 24 VDC power; Wire PROFIBUS DP (shielded twisted pair) and Ethernet (CAT5e/CAT6); Configure via Experion PKS Engineering.
Maintenance: Daily – Check LED indicators (Power, DP Status, Ethernet Link, Fault); Weekly – Verify data consistency and network latency; Annual – Inspect wiring, clean dust, update firmware.
Safety Notes: Use ESD wrist strap during handling; De-energize power before module replacement; Follow PROFIBUS installation guidelines for shielding and grounding.