BASLER ELECTRIC  ·  BE1-25A-A2-F5-V3-D0

BE1-25A-A2-F5-V3-D0 Basler BE1-25A Synchronism Check Relay

SKU: BE1-25A-A2-F5-V3-D0  |  BE1-25A Synch Check Relay  |  USA origin  |  Legacy MRO spare
Core Application
Synchronism check & voltage supervision
     Type
Synchronism check relay
     Function
Paralleling / dead bus / live bus
     Status
Legacy MRO spare

The Basler BE1-25A-A2-F5-V3-D0 is a solid-state synchronism check relay used for generator and breaker paralleling control. It verifies voltage magnitude, phase angle and frequency difference before closing the circuit breaker to prevent out-of-sync switching damage. This configuration supports live-bus, dead-bus and synchronism check modes, with adjustable setpoints, status outputs and alarm contacts. It is widely deployed in power substations, generator switchgear, CHP plants and industrial power systems.

Typical deployment: Generator breaker panel, substation bus tie breaker, auto-synchronization system, standby generator paralleling, voltage supervision, interlock for breaker closing.

image.png

Product Features

Three Core Synch Check Parameters
Monitors voltage difference, phase angle difference and frequency difference between two sources before breaker close enable.
Multiple Operating Modes
Synchronism check, live bus, dead bus, dead line supervision for flexible bus/breaker schemes.
Adjustable Setpoints
User configurable angle window, voltage tolerance, frequency window and time delay for site-specific paralleling logic.
Hardened Solid-State Design
High noise immunity, suited for harsh substation and generator switchgear EMI environments.
Status & Alarm Output Contacts
Synch OK output, fault/alarm contacts for interlock, annunciator and SCADA status indication.
Front Panel Indicators
LED status indication for synch condition, voltage presence, fault and ready-to-close status.
Generator & Bus Tie Application
Compatible with synchronous generator, cogeneration, backup generator and substation bus tie breaker control.
Standard Panel Mount
Standard relay cutout, direct drop-in replacement for existing BE1-25A installed units.

Application Scenarios

Synchronous Generator Paralleling
Permits generator breaker close only when synchronism conditions are satisfied.
Substation Bus Tie Breaker
Bus sectionalizing breaker interlock and synchronism supervision.
CHP & Cogeneration Plants
Grid parallel protection for combined heat and power generator sets.
Standby Emergency Generator
Dead bus close and source paralleling interlock for backup power systems.
Switchgear Annunciator & SCADA
Dry contact status signals for remote monitoring and alarm annunciation.
MRO Replacement Spare
Drop-in spare for existing Basler BE1-25A synchronism check relays in service switchgear.

Frequently Asked Questions

Q: What is BE1-25A-A2-F5-V3-D0?
A: Basler BE1-25A synchronism check relay, used to verify voltage, angle and frequency before closing paralleling breakers.
Q: What is the main risk of synch check failure?
A: Out-of-sync breaker closing can cause severe mechanical damage to generators, transformers and bus equipment.
Q: What happens if this relay fails?
A: Synch supervision interlock is lost; the paralleling scheme is unsafe, and the breaker close enable path is blocked or unprotected.
Q: HS code for this item?
A: HS 853649, electrical protective relay / synchronism relay.
Q: How to confirm compatibility before ordering?
A: Confirm voltage rating, operating mode, contact configuration, auxiliary supply voltage, front form factor and wiring logic.