KIMI Phone:+86 18059884790      中文版
GE
Home > GE
GE 469-P1-HI-A20-T Motor Protection
  • Warehouse: Spot
  • Warranty: 365 days
  • Quality: Original module
  • Condition: New
  • Shipping method: Courier delivery

  • Contact person: LI MING
  • Contact number: +86 18059884790
  • WeChat:18059884790
  • E-mail: plc66@qq.com

Product Description
GE Multilin (GE Vernova)  ·  469 Motor Management Relay

469-P1-HI-A20-T Motor Protection & Management Relay

SKU: 469-P1-HI-A20-T  |  P1=1A CT input  |  HI wide range power supply  |  A20 4-20mA analog output  |  T terminal version  |  EOL legacy motor spare
Core Application
Medium & low voltage motor protection
     CT Rating
1A current input
     Power Supply
HI wide range 88–300VDC /70–265VAC
     Status
Discontinued, replacement: 489 relay

The 469-P1-HI-A20-T is GE Multilin 469 series motor management relay, designed for LV/MV induction motors. P1 stands for 1A phase CT input, HI is wide-range auxiliary power supply, A20 supports 4–20mA analog output transmission, T indicates terminal configuration. It integrates thermal overload protection, locked rotor, jam, unbalance, single phasing, earth fault, over/under voltage, start inhibit, RTD temperature monitoring, FlexLogic programmable logic, COMTRADE fault recording and SOE sequence of events. Communication includes Modbus RTU, DNP3, IRIG-B time synchronization. This model is end-of-life, only available as new surplus or refurbished spare for industrial motor control cabinet retrofits.

Commonly used for pumps, fans, compressors, conveyors in oil & gas, chemical, mining, water treatment and power plant auxiliary systems.

image.png

Product Features

Full Motor Thermal & Fault Protection
Thermal overload, locked rotor, jam, current unbalance, single phase loss, earth fault, over/under voltage.
RTD Winding & Bearing Temperature Monitoring
Supports multiple PT100 RTD inputs for early over-temperature warning and trip.
Motor Start Control & Inhibit Logic
Start count, cool-down timer, restart inhibit to prevent frequent start damage to motor.
A20 4–20mA Analog Output
Convert current, temperature, load percentage to analog signal for local panel or RTU.
FlexLogic Custom Programmable Logic
Custom interlock, alarm, control logic without external PLC for motor control schemes.
Fault Oscillography & Event Logging
COMTRADE waveform capture, SOE records, IRIG-B time sync for fault troubleshooting.
Multi-Protocol Serial Communication
Modbus RTU, DNP3 over RS485, compatible with SCADA and DCS systems.
HI Wide Range Auxiliary Power
88–300VDC /70–265VAC, fits mixed AC/DC control power in industrial cabinets.

Application Scenarios

LV & MV Induction Motor Protection
Pumps, fans, compressors, crushers, belt conveyors main protection.
Water & Wastewater Treatment Plants
Submersible pump, blower motor monitoring and protection for water treatment stations.
Oil, Gas & Chemical Process Plants
Process motor protection with DCS/SCADA remote monitoring and alarm upload.
Power Plant Auxiliary Motors
Boiler feed pump, induced draft fan, forced draft fan motor management.
Mining & Heavy Industry Motors
Harsh environment heavy load motor protection with jam and locked rotor detection.
Legacy MCC Cabinet Retrofit & Spare
Drop-in replacement for existing 469 relays in running motor control centers.

Frequently Asked Questions

Q: What is 469-P1-HI-A20-T?
A: GE Multilin 469 motor management relay, 1A CT input, HI wide power supply, A20 4-20mA analog output, T terminal version.
Q: What does P1 stand for?
A: P1 = 1A secondary current input; P5 variant is for 5A CT.
Q: Is this relay still in production?
A: No, GE Vernova discontinued 469 series; recommended successor model is 489 motor relay.
Q: What is A20 function?
A: A20 provides configurable 4–20mA analog output channels for temperature, load current and motor load factor.
Q: Can it monitor motor winding temperature?
A: Yes, it supports PT100 RTD inputs for winding and bearing temperature monitoring and alarm/trip.
Q: What is the difference between 469 and 750?
A: 469 is dedicated motor protection relay with thermal model and start control; 750 is feeder protection relay for distribution feeders.
Q: What communication does it support?
A: Modbus RTU, DNP3 over RS485, IRIG-B time sync.
Q: How to confirm compatibility before ordering?
A: Confirm CT ratio (1A/5A), power supply range, RTD requirement, analog output option, I/O allocation and terminal layout.


Related recommendations