KIMI Phone:+86 18059884790      中文版
GE
Home > GE
GE 745-W2-P1-G1-HI-T Transformer Protection
  • Warehouse: Spot
  • Warranty: 365 days
  • Quality: Original module
  • Condition: New
  • Shipping method: Courier delivery

  • Contact person: LI MING
  • Contact number: +86 18059884790
  • WeChat:18059884790
  • E-mail: plc66@qq.com

Product Description
GE Multilin (GE Vernova)  ·  745 Transformer Management Relay

745-W2-P1-G1-HI-T Transformer Protection & Management Relay

SKU: 745-W2-P1-G1-HI-T  |  2-winding transformer  |  HI high accuracy metering  |  Drawout chassis  |  EOL legacy power protection spare
Core Protection
Transformer differential protection
     Metering
HI high precision metering
     Comm Protocol
Modbus TCP, DNP3, IRIG-B
     Status
Discontinued, replacement: 845 relay

The 745-W2-P1-G1-HI-T is GE Multilin 745 series drawout transformer management relay, designed for two-winding power transformers. It adopts restrained differential protection with 2nd / 5th harmonic blocking to avoid false tripping during transformer inrush. It integrates full backup protection, OLTC on-load tap changer control, high accuracy metering, FlexLogic programmable logic, COMTRADE waveform capture and sequence of event recording. This W2=2-winding, P1 base I/O, G1 communication variant with HI high precision metering, T suffix for chassis/terminal configuration. Original production discontinued, only available as new surplus, refurbished spare for utility and industrial substation retrofit.

Supports Ethernet, RS232, RS485 multi-port communication, connects to SCADA and substation automation system, widely used for HV/MV main transformer protection in power plant, substation, oil & gas and mining power systems.

image.png

Product Features

Ratio Restraint Differential Protection
2nd & 5th harmonic inrush blocking, reliable internal fault detection, stable for through fault.
Complete Backup Protection Suite
Phase overcurrent, neutral / ground overcurrent, restricted earth fault, overfluxing, thermal overload, frequency protection.
OLTC On-Load Tap Changer Control
Tap position monitoring, auto voltage regulation, tap change blocking and fault alarm logic.
HI High Accuracy Metering
Three-phase voltage, current, power, power factor, harmonics and energy measurement for power quality monitoring.
FlexLogic Custom Programmable Logic
Built-in logic engine, implement interlock, automation and alarm schemes without external PLC.
Fault Recording & Time Sync
COMTRADE oscillography, event sequence report, IRIG-B time synchronization for fault analysis.
Multi-Interface Communication
Ethernet, RS232, RS485; Modbus TCP, DNP3.0, suitable for SCADA and substation automation.
Drawout Plug-In Structure
Hot withdrawable module, convenient maintenance and quick replacement for substation spare plan.

Application Scenarios

Two-Winding Power Transformer Main Protection
Distribution substation, power plant auxiliary transformer differential and backup protection.
Industrial Heavy-Duty Power Systems
Oil & gas, chemical, mining, steel plant main transformer monitoring and protection.
Renewable Energy Collector Substation
Wind farm / solar booster station transformer protection and OLTC regulation.
SCADA Substation Automation
Remote metering, alarm uploading and event reporting for power dispatch system.
Legacy Substation Retrofit
Drop-in replacement for existing 745 series relays in running stations.
Power System Fault Analysis
Waveform capture, fault location and post-event analysis for power quality troubleshooting.

Frequently Asked Questions

Q: What is 745-W2-P1-G1-HI-T?
A: GE Multilin 745 drawout transformer management relay for two-winding transformers, with high accuracy metering, differential protection and OLTC control.
Q: What does W2 / HI stand for?
A: W2 = 2-winding transformer configuration; HI = high accuracy metering option.
Q: Is this relay still in production?
A: No, GE Vernova discontinued 745 series; recommended successor model is 845 transformer protection relay.
Q: What is the core protection principle?
A: Percentage restrained differential protection with 2nd / 5th harmonic blocking to prevent inrush misoperation.
Q: Does it support OLTC tap changer control?
A: Yes, built-in tap position monitoring, voltage regulation and tap change blocking logic.
Q: What communication protocols are supported?
A: Modbus TCP, DNP3.0, IRIG-B time sync, Ethernet + RS485/RS232 ports.
Q: What is FlexLogic?
A: GE’s internal programmable logic function, custom interlock, alarm and automation logic without external PLC.
Q: How to confirm compatibility before ordering?
A: Confirm winding count, I/O allocation, communication option, metering grade, drawout chassis type and firmware version.


Related recommendations