Product Description
Honeywell  ·  Excel Web II BACnet Building Controller

XL2000B2A Excel Web II Building Controller

SKU: XL2000B2A  |  Excel Web II  |  Built-in HMI  |  No onboard I/O  |  Max 600 distributed I/O  |  BACnet IP / MS/TP + LONWORKS
I/O Capacity
Max 600 distributed I/O
     HMI
Integrated HMI, no external HMI support
     Protocol
BACnet IP, MS/TP, LONWORKS
     Programming
CARE software

The XL2000B2A is Honeywell Excel Web II freely programmable BACnet Building Controller (B-BC) for building automation and HVAC systems. It has no onboard I/O, supports up to 600 distributed I/O points via expansion modules, and comes with built-in local HMI. It cannot connect to the external XL2000HMI-A panel. It supports native BACnet IP / BACnet MS/TP and optional LONWORKS with IF-LON module, and integrates into Honeywell EBI and SymmetrE management platforms.

This controller is used for central HVAC, energy management, lighting, blind control and metering. It can run standalone or peer-to-peer without a top-level supervisory controller, widely stocked as spare for legacy building automation retrofit and maintenance projects.

image.png

Product Features

Native BACnet Building Controller B-BC
Compliant BACnet IP and BACnet MS/TP, easy interoperability with third-party BACnet devices.
Built-in HMI, No Onboard I/O
Local display and operation integrated; no physical onboard I/O, all points via distributed I/O modules.
Max 600 Distributed I/O Points
Large point capacity for medium and large building automation supervisory control applications.
Optional LONWORKS Interface
Add IF-LON module to communicate with Honeywell and 3rd-party LONWORKS field devices.
CARE Programming Environment
Freely programmable with Honeywell CARE tool for HVAC sequences, energy logic and schedules.
Peer-to-Peer & Standalone Operation
Can work independently or exchange data peer-to-peer, not relying on supervisory host.
Energy & HVAC Advanced Functions
Optimum start-stop, night purge, peak demand limiting, scheduling and consumption metering.
Compatible with EBI / SymmetrE
Native integration into Honeywell enterprise building management systems for central monitoring.

Application Scenarios

Central HVAC Supervisory Control
AHU, chiller, boiler, VAV system coordination and temperature/humidity regulation.
Building Energy Management
Load shedding, demand control, schedule optimization and energy consumption monitoring.
Lighting & Sun Blind Control
Time schedule, daylight harvesting and group control for commercial buildings.
Energy Metering & Substation Monitoring
Water, electricity, gas meter data collection and alarm supervision.
Legacy BAS Maintenance Spares
Replacement controller for existing Excel Web II building automation systems.
Commercial & Public Buildings
Office, hospital, hotel, data center and shopping mall automation projects.

Frequently Asked Questions

Q: What is XL2000B2A?
A: Honeywell Excel Web II BACnet building controller, built-in HMI, no onboard I/O, up to 600 distributed I/O points for HVAC and building automation.
Q: Can I add external XL2000HMI-A?
A: No, XL2000B2A has integrated HMI and does not support external XL2000HMI-A panel.
Q: What software is used for programming?
A: Honeywell CARE (Computer Aided Regulation Engineering) software.
Q: What communication protocols are supported?
A: BACnet IP, BACnet MS/TP; LONWORKS available with IF-LON module.
Q: What is the difference between XL2000B2A and XL2000B3A?
A: XL2000B2A = built-in HMI, no external HMI port; XL2000B3A = no built-in HMI, RJ45 port for XL2000HMI-A external panel.
Q: What power supply does it use?
A: 24VAC standard building controller power supply.
Q: Can it run without a supervisory server?
A: Yes, it supports standalone and peer-to-peer control independent of upper host system.
Q: How to confirm compatibility before ordering?
A: Verify CARE program version, I/O expansion modules list, BACnet topology and whether external HMI is required.