ABB SPAU130 C-AA Three‑Phase Overvoltage
  • Warehouse: Spot
  • Warranty: 365 days
  • Quality: Original module
  • Condition: New
  • Shipping method: Courier delivery

  • Contact person: LI MING
  • Contact number: +86 18059884790
  • WeChat:18059884790
  • E-mail: plc66@qq.com

Product Description
ABB  ·  SPACOM Series

ABB SPAU130 C-AA Three‑Phase Overvoltage & Undervoltage Relay

The ABB SPAU130 C-AA is a legacy numerical voltage protection relay from the SPACOM family, designed for three-phase overvoltage and undervoltage supervision. It is widely used in distribution substations, generators, transformers and motor circuits, supplied as spare replacement for existing ABB protection panels.

image.png

Model: SPAU130 C-AA      Series: SPACOM SPAU130C      Status: Obsolete / Legacy Spare      Function: Overvoltage + Undervoltage      Origin: Finland      Warranty: 12 Months
Request Price & Lead Time      Ask for Test Report

Product Overview

ABB SPAU130 C-AA is a three-phase voltage monitoring relay belonging to the ABB SPACOM protection family. It measures phase-to-phase voltages and provides combined overvoltage and undervoltage protection. The overvoltage stage supports both inverse time and definite time characteristics, while the undervoltage stage uses definite time only. It can be configured for three-phase or single-phase measurement, with fibre-optic bus communication for substation automation. ABB discontinued this model since 2009, it is mainly available as NOS or refurbished spare parts for maintenance and replacement.

Product typeThree-phase voltage protection relay
MeasurementPhase-to-phase voltage, 3-phase or single-phase mode
Protection stagesOvervoltage (IDMT / Definite Time), Undervoltage (Definite Time)
CommunicationSerial interface, fibre-optic substation bus
Weight3.15 kg

Key Features & Functions

Core protection and monitoring functions of the SPAU130 C-AA relay.

01

Overvoltage protection stage

Supports inverse time IDMT or definite time operating characteristics for high voltage excursion protection.

02

Undervoltage protection stage

Definite time undervoltage supervision, prevents simultaneous motor restart after voltage recovery.

03

External blocking input

External control input to block undervoltage function; auto-blocking when auxiliary supply is lost.

04

Configurable output matrix

User-assignable output relays for trip, alarm and interlock signals to match site protection schemes.

05

Local display & fault recording

Front display shows measured voltage, parameters and stored fault values for post-event analysis.

06

Self-supervision diagnostics

Continuous hardware and firmware self-monitoring with fault indication for rapid troubleshooting.

Application Scenarios

Typical installation and replacement scenarios for SPAU130 C-AA.

Distribution Substation Busbar Supervision

Voltage monitoring and protection for MV busbars in utility distribution substations.

Generator Voltage Protection

Overvoltage and undervoltage supervision for synchronous generators in power plants.

Transformer Protection

Voltage abnormal protection for power transformers in industrial and utility systems.

Large Motor Feeder Control

Undervoltage protection to avoid massive motor inrush after voltage restoration.

Legacy SPACOM Panel Retrofit

Drop-in spare replacement for existing ABB SPACOM protection panels, avoiding full panel upgrade.

Renewable Power Station

Maintenance spare for old wind or solar farm voltage protection panels.

Frequently Asked Questions

Q. Is SPAU130 C-AA still in production?

No. ABB stopped production of SPAU130C series since 2009. It is only available as new old stock or professionally refurbished spare parts.

Q. What is the difference between SPAU130 C-AA and SPAU130 C-CA?

AA and CA are different auxiliary supply / frequency variants. They cannot be swapped directly; you must match the suffix, rated frequency and auxiliary voltage of your original unit.

Q. Can it work in single-phase voltage mode?

Yes. The relay can be programmed for either three-phase phase-to-phase measurement or single-phase voltage supervision.

Q. Can the undervoltage stage use inverse time curve?

No. Only the overvoltage stage supports IDMT inverse time curve; undervoltage stage is fixed definite time.

Q. How to configure and read fault data?

Settings can be entered via front panel or remote software over fibre-optic SPACOM bus. Fault snapshots and measured values are stored locally for review.

Q. Are units tested before shipment?

All SPAU130 C-AA units are fully function tested. Test report can be provided upon request, standard warranty is 12 months.

Need SPAU130 C-AA spare for your SPACOM protection panel?

Send us the relay label photo, auxiliary voltage and frequency requirement, we will verify compatibility and quote price and lead time quickly.