KIMI Phone:+86 18059884790      中文版
ALSTOM
Alstom VP32702X (VP327 02X) + MV7306P21 Servo Valve Assembly for Steam Turbine DEH
  • Warehouse: Spot
  • Warranty: 365 days
  • Quality: Original module
  • Condition: New
  • Shipping method: Courier delivery

  • Contact person: LI MING
  • Contact number: +86 18059884790
  • WeChat:18059884790
  • E-mail: plc66@qq.com

Product Description

Alstom VP32702X (VP327 02X) + MV7306P21 Servo Valve Assembly for Steam Turbine DEH

Product Description

The VP32702X (VP327 02X) is a high-performance two-stage hydraulic servo valve originally from Alstom (later GE Vernova), matched with MV7306P21 as the complete valve assembly. It is the core actuator for steam turbine DEH digital electro-hydraulic control system, designed for phosphate ester EH anti-flame fuel. It converts 4–20mA electric command signal into proportional hydraulic flow, precisely controlling the opening of turbine high-pressure regulating valves, realizing closed-loop speed and load regulation for thermal power units.

image.png

  • Part Number: VP32702X / VP327 02X, Assembly Code: MV7306P21, Brand: Alstom / GE Vernova
  • Structure: Two-stage nozzle-flapper torque motor, mechanical feedback, 4-way spool
  • Control signal: 4–20mA standard analog command signal
  • Working fluid: EH fire-resistant phosphate ester hydraulic oil
  • Max working pressure: 16 MPa, optimized for turbine EH oil system
  • Performance: Low dead zone, high resolution, fast response, anti-stiction design for long-term continuous operation
  • Material: Hard alloy spool and sleeve, special seal material compatible with EH fluid
  • Mounting: Standard manifold mounting pattern for steam turbine hydraulic actuator
  • Certifications: CE, meets power plant DEH control specification
  • Manufacturer Status: EOL legacy turbine spare; aftermarket supply: NOS surplus, calibrated refurbished units
  • Typical gross weight: approx 3.6 kg, origin: France
  • Matched system: Alstom / GE steam turbine DEH, 600MW / 1000MW supercritical & ultra-supercritical units

Applications

  • Thermal power plant steam turbine high-pressure governing valve hydraulic actuation
  • DEH system closed-loop speed, load control and primary frequency modulation
  • Power plant EH oil system overhaul, spare replacement and DEH retrofit
  • Coal-fired, combined-cycle turbine governing control skid

FAQ

Q: What is the relation between VP32702X and MV7306P21?
A: VP32702X is the servo valve core body; MV7306P21 is the full assembly part number including valve, manifold, connectors and test report, sold as one complete set.

Q: Can it use ordinary mineral hydraulic oil?
A: Not recommended. It is specially built for phosphate ester EH fire-resistant oil; mineral oil will cause seal swelling and valve failure.

Q: Common failure points?
A: Nozzle blockage, spool stiction, torque motor coil damage, seal aging; overhaul needs cleaning, zero/span calibration and dynamic test on servo valve bench.


Related recommendations