GE MIVII1000E00HI00 Digital Voltage
Time:2025-04-07 08:49:23   View count:
GE Multilin (GE Vernova)  ·  MIVII1000E00HI00 Voltage & Frequency Relay

MIVII1000E00HI00 Digital Voltage & Frequency Protection Relay

SKU: MIVII1000E00HI00  |  MII series voltage/frequency relay  |  HI wide range power supply  |  Isolated RS232  |  EOL legacy power spare
Core Application
Bus, generator voltage & frequency protection
     Power Supply
88–300VDC / 88–264VAC wide range
     Comm Port
Isolated RS232
     Status
End of life, surplus/refurbished only

The MIVII1000E00HI00 is GE Multilin MII series digital voltage and frequency relay, dedicated to voltage and frequency supervision protection for busbars, generators, transformers and distribution feeders. HI denotes wide-range universal auxiliary power supply; E00 and 00 denote base I/O configuration without extra options. It provides overvoltage, undervoltage, voltage unbalance, overfrequency, underfrequency, rate-of-change of frequency (ROCOF) and vector shift protection, widely used for generator islanding detection, loss of mains and busbar voltage supervision. It supports programmable timers, FlexLogic, event recording and local metering. Communication is via isolated RS232 port. This model is discontinued, stocked as surplus or refurbished spare for substation and generator panel retrofit.

Typical deployment: generator anti-islanding protection, grid interconnection protection, bus voltage supervision for power plant auxiliary systems and renewable interconnection cabinets.

image.png

Product Features

Voltage Protection Functions
Overvoltage, undervoltage, negative sequence voltage unbalance, loss of voltage detection.
Frequency & ROCOF Protection
Over/under frequency, df/dt ROCOF, vector shift, ideal for generator islanding detection.
Wide Range HI Auxiliary Supply
88–300VDC / 88–264VAC, compatible with mixed AC/DC substation control power.
Isolated RS232 Communication
Local serial port for configuration, reading metering data and event logs.
FlexLogic Programmable Logic
Custom interlock, alarm, trip logic for grid interlock and islanding schemes.
Event Sequence & Metering
SOE event logging, three-phase voltage metering, frequency and negative sequence monitoring.
Adjustable Timing Curves
Independent pickup and time delay setting for each protection element.
Compact Panel Mount Design
Standard panel cutout, fits alongside 469/750/745 relays in existing relay panels.

Application Scenarios

Generator Islanding & Loss of Mains Protection
ROCOF + vector shift anti-islanding for synchronous generators and DG interconnection.
Busbar Voltage Supervision
Main and auxiliary bus undervoltage/overvoltage supervision for power plant substations.
Renewable Energy Grid Interconnection Cabinets
Solar / wind interconnection voltage and frequency protection before grid-tie inverter.
Industrial Cogeneration Systems
CHP generator grid interlock protection for chemical, oil & gas and steel plants.
Backup Voltage Protection for Transformers & Feeders
Complementary voltage protection paired with 745 transformer relay and 750 feeder relay.
Legacy Panel Retrofit & Replacement Spare
Direct replacement for existing MII series voltage/frequency relays in running substation panels.

Frequently Asked Questions

Q: What is MIVII1000E00HI00?
A: GE Multilin MII series digital voltage and frequency relay, used for over/under voltage, frequency, ROCOF and islanding protection.
Q: What does HI stand for?
A: HI = wide-range universal auxiliary power supply (88–300VDC / 88–264VAC).
Q: What is ROCOF and vector shift used for?
A: ROCOF (df/dt) and vector shift are core islanding detection elements for generator grid interconnection protection.
Q: Does it support Modbus TCP?
A: This base variant only has isolated RS232; Modbus Ethernet is not fitted on this E00 base version.
Q: What is the difference between MIVII1000E00HI00 and 750?
A: MIVII1000 is dedicated voltage/frequency islanding relay; 750 is feeder overcurrent relay with voltage backup functions.
Q: Can it be used for solar grid-tie protection?
A: Yes, it is widely used for DG interconnection anti-islanding, subject to local grid code requirements.
Q: How to confirm compatibility before ordering?
A: Confirm VT ratio, auxiliary power range, required protection elements, communication interface and panel cutout size.