Alstom / AREVA / GE Vernova  ·  MVAJ Series High Speed Self-Reset Tripping Relay

MVAJ101RA0800A Self-Reset Tripping Relay

SKU: MVAJ101RA0800A  |  MVAJ101  |  Draw-out plug-in  | <20ms operate time  |  Multi-contact trip relay  |  Substation protection panel spare
Operation Time
Typical<20ms
Contact
10 contacts, NO/NC mixed
     Feature
Self-reset, economizer circuit
     Mounting
Draw-out plug-in Midos size 4

The MVAJ101RA0800A is a high-speed self-reset tripping relay from Alstom/AREVA MVAJ relay family, now part of GE Vernova Grid Solutions. It receives trip command signals from protection relays and provides multiple isolated contact outputs for circuit breaker trip coils, alarm signals and interlock loops. It automatically resets once the trip input signal disappears, with built-in economizer circuit to reduce holding power consumption. It supports high/low burden selection for long field cables or cabinet internal wiring, widely used as spare for legacy power substation protection panels.

This is a legacy electromechanical protection relay, deployed in HV/MV switchgear protection schemes. The transparent front cover allows direct visual inspection of armature and contact status without disassembly.

image.png

Product Features

High Speed Trip Response
Typical operate time below 20ms, low contact bounce, critical for fast protection tripping logic.
Self-Reset Mechanism
Auto reset after removal of trip input pulse; magnetic residual gap ensures reliable reset action.
High / Low Burden Selectable
High burden mode for long cable runs and capacitive discharge; low burden for short cabinet wiring.
Built-in Economizer Circuit
Reduces holding power after actuation, high burden version delays economizing for 40–60ms.
Multi NO/NC Contact Bank
10 mixed normally open and normally closed contacts for distributing trip, alarm and interlock signals.
Draw-out Plug-in Midos Housing
Midos size 4 form factor, hot swap replacement without full panel wiring removal.
Transparent Inspection Cover
Visual status check of armature and contacts without opening the relay housing.
Legacy Protection Spare
Original production discontinued, mainly stocked for maintenance of existing substation protection panels.

Application Scenarios

HV/MV Substation Protection Panels
Interface between protection IEDs and circuit breaker trip coils.
Switchgear Trip & Interlock Logic
Fast trip distribution, blocking interlock and fault alarm signal routing.
Power Plant Auxiliary Protection
Generator, transformer and busbar protection auxiliary tripping circuits.
Industrial Power Distribution
Heavy industry, refinery and mining high voltage power system protection.
Retrofit & Maintenance Spares
Replacement for existing Alstom/AREVA MVAJ relay protection schemes.
Feeder Protection Auxiliary Relay
Multi-channel trip output expansion for numerical protection relays.

Frequently Asked Questions

Q: What is MVAJ101RA0800A?
A: Alstom/AREVA MVAJ101 high-speed self-reset tripping relay, used for breaker trip amplification, alarm and interlock in power protection panels.
Q: What is the difference between MVAJ101 and MVAJ201?
A: Both are self-reset; MVAJ101 is the standard version with economizer hold, MVAJ201 has higher contact rating and different timing characteristic.
Q: What does high burden mode mean?
A: High burden mode can drive long control cables with large capacitance, suitable for breaker trip coils located far away from the protection panel.
Q: Is this relay hand-reset or self-reset?
A: Self-reset type; it automatically resets once the input trip pulse signal disappears, no manual reset required.
Q: What is the operating temperature range?
A: -10°C to +55°C, for indoor substation cabinet installation, non-condensing environment.
Q: Can I replace it with MVAJ103 directly?
A: Not direct plug-and-play; MVAJ103 is zero-watt cut-off variant, link configuration and circuit logic differ, check schematic before swap.
Q: What coil voltage is MVAJ101RA0800A?
A: The full suffix defines coil DC voltage; confirm coil rating, terminal link position and burden setting before power on.
Q: How to confirm compatibility before ordering?
A: Verify coil voltage, burden setting, contact layout, wiring schematic and existing MVAJ link configuration.