Allen‑Bradley 1715‑IF16 Redundant Analog Input Module
Product Description
The 1715‑IF16 is a 16‑point analog input module for Rockwell Allen‑Bradley Bulletin 1715 redundant I/O system. It is designed for high‑availability process control applications, supporting simplex and duplex redundant configurations. It receives 4‑20mA analog signals from field transmitters and sends data to the ControlLogix controller via 1715‑AENTR EtherNet/IP adapter. It supports hot‑swap replacement without interrupting the control process, widely used in safety‑critical process industries.

Features
- Part Number: 1715‑IF16, Brand: Allen‑Bradley (Rockwell Automation)
- Series: 1715 Redundant I/O Series
- Channel: 16 isolated analog input channels, signal type: 4‑20 mA
- Working mode: Simplex (single) / Duplex (redundant pair) configurable
- Base required: 1715‑A3IO module base
- Matching termination assemblies: 1715‑TASIF16 (simplex), 1715‑TADIF16 (duplex)
- Function: Built‑in comprehensive diagnostics, wire break detection, out‑of‑range alarm
- Hot swap: RIUP – Remove and Insert Under Power supported
- Certifications: cULus, CE, Class I Division 2 hazardous location approval
- Manufacturer Status: Active, available as original new, surplus or refurbished
- Typical gross weight: approx 0.45 kg, origin: Mexico
- Response time: 120 ms for module data update
Applications
- Oil & gas, refinery, petrochemical process control systems
- Power plant, water treatment, chemical plant high‑reliability PLC control
- Process safety systems, SIL‑related control cabinet spare parts
- ControlLogix platform redundant I/O retrofit and spare inventory
- Offshore platform, compressor station continuous process monitoring
FAQ
Q: What is the difference between simplex and duplex mode for 1715‑IF16?
A: Simplex uses one single module; duplex uses two identical 1715‑IF16 modules for redundant I/O, if one fails the other takes over automatically.
Q: Can it work directly with ControlLogix rack without 1715‑AENTR?
A: No, the 1715 I/O system requires 1715‑AENTR EtherNet/IP adapter to communicate with ControlLogix CPU.
Q: Does this module support 0‑10V voltage input?
A: No, 1715‑IF16 only supports 4‑20mA current signal input.